Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
10 |
105℃ |
41/0.405 |
2C |
1.14 |
1.5 |
5.35/14.1 |
10 |
105℃ |
41/0.405 |
3G |
1.14 |
1.5 |
5.35/14.8 |
10 |
105℃ |
41/0.405 |
4G |
1.14 |
1.5 |
5.35/16.3 |
12 |
105℃ |
65/0.254 |
2C |
0.76 |
1.1 |
3.95/10.6 |
12 |
105℃ |
65/0.254 |
3G |
0.76 |
1.1 |
3.95/11.1 |
12 |
105℃ |
65/0.254 |
4G |
0.76 |
1.1 |
3.95/12.1 |
12 |
105℃ |
65/0.254 |
5G |
0.76 |
1.1 |
3.95/13.3 |
14 |
105℃ |
41/0.254 |
2C |
0.76 |
0.7 |
3.45/8.7 |
14 |
105℃ |
41/0.254 |
3G |
0.76 |
0.7 |
3.45/9.5 |
14 |
105℃ |
41/0.254 |
4G |
0.76 |
0.7 |
3.45/10.2 |
Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
14 |
105℃ |
41/0.254 |
5G |
0.76 |
0.7 |
3.45/11.2 |
16 |
105℃ |
26/0.254 |
2C |
0.76 |
0.7 |
3.1/8 |
16 |
105℃ |
26/0.254 |
3G |
0.76 |
0.7 |
3.1/8.5 |
16 |
105℃ |
26/0.254 |
4G |
0.76 |
0.7 |
3.1/9.2 |
16 |
105℃ |
26/0.254 |
5G |
0.76 |
0.7 |
3.1/10.2 |
18 |
105℃ |
41/0.16 |
2C |
0.76 |
0.7 |
2.8/7.3 |
18 |
105℃ |
41/0.16 |
3G |
0.76 |
0.7 |
2.8/7.9 |
18 |
105℃ |
41/0.16 |
4G |
0.76 |
0.7 |
2.8/8.5 |
18 |
105℃ |
41/0.16 |
5G |
0.76 |
0.7 |
2.8/9.5 |
18 |
105℃ |
41/0.16 |
6G |
0.76 |
0.7 |
2.8/10.25 |
Standard: UL62 Table 6.12 Oil-resistant hard-service cords .
Maximum voltage: 300V. Rated temperature: 90~105℃ .
Conductors material: Soft-annealed copper(7.1 and 7.2).
Insulation and jacket material: TPE.
Number of circuit conductors 2-5, AWG size of circuit conductors 18-10.
The O in the type letters indicates that the jacket is for continuous immersion in oil.
The OO in the type letters indicates that both the insulation & jacket are for continuous immersion in oil.
The W in the type letters indicates that suitable for outdoor.