Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
16 |
80℃ |
26/0.254 |
16/2Pairs |
0.38 |
0.76 |
7.21 |
18 |
80℃ |
41/0.16 |
18/2Pairs |
0.38 |
0.76 |
6.49 |
20 |
80℃ |
21/0.18 |
20/2Pairs |
0.38 |
0.76 |
5.96 |
20 |
80℃ |
21/0.18 |
20/3Pairs |
0.38 |
0.76 |
6.9 |
22 |
80℃ |
7/0.254 |
22/2Pairs |
0.38 |
0.76 |
5.55 |
22 |
80℃ |
7/0.254 |
22/3Pairs |
0.38 |
0.76 |
6.4 |
24 |
80℃ |
11/0.16 |
24/2Pairs |
0.38 |
0.76 |
5.17 |
24 |
80℃ |
11/0.16 |
24/3Pairs |
0.38 |
0.76 |
5.94 |
26 |
80℃ |
7/0.16 |
26/2Pairs |
0.38 |
0.76 |
4.89 |
26 |
80℃ |
7/0.16 |
26/3Pairs |
0.38 |
0.76 |
5.59 |
Standard: Appliance wiring material UL 758.
Rated voltage: 300V. Rated temperature: 80℃ .
Conductor: Different conductor sizes may be used in one cord.
Assembly: Consists of two or more conductors, twisted pairs or groups of twisted
conductors twisted together. The conductors or groups of conductors may be laid parallel
forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier
layer and/or fillers are optional. Manufacturer shall maintain a complete description of
each assembly. May use same or mixed AWG size.
Covering: (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor
assembly.
Shield: Optional.
Passed UL VW-1 flame test.
Construction A, Internal wiring of x-ray equipment; or internal wiring of electronic
equipment.
Construction B, External interconnection of electronic equipment in abuse areas (such as
x-ray equipment and business machines).