Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
16 |
60℃ |
26/0.254 |
16/2Pairs |
0.5 |
1.14 |
7.47 |
18 |
60℃ |
41/0.16 |
18/2Pairs |
0.5 |
1.14 |
6.85 |
20 |
60℃ |
21/0.18 |
20/2Pairs |
0.5 |
1.14 |
6.39 |
22 |
60℃ |
7/0.254 |
22/2Pairs |
0.5 |
1.14 |
6.03 |
24 |
60℃ |
11/0.16 |
24/2Pairs |
0.5 |
1.14 |
5.71 |
24 |
60℃ |
11/0.16 |
24/3Pairs |
0.5 |
1.14 |
5.96 |
Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
26 |
60℃ |
7/0.16 |
26/2Pairs |
0.5 |
1.14 |
5.46 |
26 |
60℃ |
7/0.16 |
26/3Pairs |
0.5 |
1.14 |
5.69 |
28 |
60℃ |
7/0.127 |
28/2Pairs |
0.5 |
1.14 |
5.26 |
28 |
60℃ |
7/0.127 |
28/3Pairs |
0.5 |
1.14 |
5.47 |
30 |
60℃ |
7/0.10 |
30/2Pairs |
0.5 |
1.14 |
5.09 |
30 |
60℃ |
7/0.10 |
30/3Pairs |
0.5 |
1.14 |
5.29 |
Standard: Appliance wiring material UL 758.
Rated voltage: Not specified. Rated temperature: 60℃ .
PVC insulation and jacket.
Assembly: Consists of two or more conductors, twisted pairs or groups of twisted conductors
twisted together. The conductors or groups of conductors may be laid parallel forming a flat,
oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are
optional. Manufacturer shall maintain a complete description of each assembly. May use same
or mixed AWG size.
Covering: (Optional) - A 6 mil or heavier PVC covering may be extruded over the conductor
assembly.
Shield: (Optional)
Passed UL VW-1 flame test.
External interconnection of electronic equipment.