Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
16 |
105℃ |
26/0.254 |
16/2Pairs |
0.38 |
0.76 |
7.21 |
18 |
105℃ |
41/0.16 |
18/2Pairs |
0.38 |
0.76 |
6.49 |
20 |
105℃ |
21/0.18 |
20/2Pairs |
0.38 |
0.76 |
5.96 |
22 |
105℃ |
7/0.254 |
22/2Pairs |
0.38 |
0.76 |
5.55 |
24 |
105℃ |
11/0.16 |
24/2Pairs |
0.38 |
0.76 |
5.17 |
24 |
105℃ |
11/0.16 |
24/3Pairs |
0.38 |
0.76 |
5.94 |
Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
26 |
105℃ |
7/0.16 |
26/2Pairs |
0.38 |
0.76 |
4.89 |
26 |
105℃ |
7/0.16 |
26/3Pairs |
0.38 |
0.76 |
5.59 |
28 |
105℃ |
7/0.127 |
28/2Pairs |
0.38 |
0.76 |
4.65 |
28 |
105℃ |
7/0.127 |
28/3Pairs |
0.38 |
0.76 |
5.3 |
30 |
105℃ |
7/0.10 |
30/2Pairs |
0.38 |
0.76 |
4.46 |
30 |
105℃ |
7/0.10 |
30/3Pairs |
0.38 |
0.76 |
5.07 |
Standard: Appliance wiring material UL 758.
Rated voltage: 300V. Rated temperature: 105℃ .
PVC insulation and jacket.
Assembly: Consists of two or more singles, twisted pairs or groups of twisted singles twisted
together. The singles or groups of singles may be laid parallel forming a flat, oval or round
cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional.
Manufacturer shall maintain a complete description of each assembly. May use same or mixed
AWG size.
Covering: (Optional) - A 6 mil or heavier PVC covering may be extruded over the conductor
assembly.
Shield: (Optional)
Passed UL VW-1 flame test.
External interconnection of electronic equipment or internal wiring of electronic equipment or appliances.