Conductor Size mm² |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) Technical Details |
0.75mm² |
|
24/0.20 |
|
0.5 |
0.6 |
2 core circular 6.1 |
0.75mm² |
|
24/0.20 |
|
0.5 |
0.6 |
3 core circular 6.5 |
0.75mm² |
|
24/0.20 |
|
0.5 |
0.6 |
2 core flat 3.9 X 6.1 |
0.75mm² |
|
Tinsel |
|
0.5 |
0.6 |
2 core flat 3.8 X 5.9 |
Standard: AS 3191 2.10.12-PVC insulated and sheathed cords.
Rated voltage: 250/250V.
Maximum conductor operation temperature: 75℃ .
Conductor: Bare or tinned copper
Insulation: PVC V-75.
Jacket material: 4V-75.
The minimum insulation thickness is calculated by the following formula:
T min.= Tnom.-10% Tnom. - 0.1mm
The minimum sheath thickness is calculated by the following formula:
T min.= Tnom.- 15% Tnom. - 0.1mm
The outer diameters are informative and not normative.
The construction is similar to that of H03VV-F.
Suitable for indoor small electrical instruments power supply wire.