Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
16 |
60℃ |
26/0.254 |
|
0.38 |
0.38 |
6.45 |
18 |
60℃ |
41/0.16 |
|
0.38 |
0.38 |
5.73 |
20 |
60℃ |
21/0.18 |
|
0.38 |
0.38 |
5.2 |
22 |
60℃ |
7/0.254 |
|
0.38 |
0.38 |
4.79 |
24 |
60℃ |
11/0.16 |
|
0.38 |
0.38 |
4.41 |
24 |
60℃ |
11/0.16 |
|
0.38 |
0.38 |
5.18 |
Conductor Size AWG |
Temperature ℃ |
Conductor No./mm |
No. of Core |
Insulation Thickness (mm) |
Jacket Thickness (mm) |
OD (±0.1mm) |
26 |
60℃ |
7/0.16 |
|
0.38 |
0.38 |
4.13 |
26 |
60℃ |
7/0.16 |
|
0.38 |
0.38 |
4.83 |
28 |
60℃ |
7/0.127 |
|
0.38 |
0.38 |
3.89 |
28 |
60℃ |
7/0.127 |
|
0.38 |
0.38 |
4.54 |
30 |
60℃ |
7/0.10 |
|
0.38 |
0.38 |
3.7 |
30 |
60℃ |
7/0.10 |
|
0.38 |
0.38 |
4.31 |
Standard: Appliance wiring material UL 758.
Rated voltage: 300V. Rated temperature: 60℃
Insulation: PE or FRPE
Jacket: PVC
Assembly: Consists of two or more conductors, twisted pairs or groups of twisted
conductors twisted together. The conductors or groups of conductors may be laid parallel
forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier
layer and/or fillers are optional. Manufacturer shall maintain a complete description of
each assembly. May use same or mixed AWG size.
Covering: (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor
assembly.
Shield: Optional.
Passed UL VW-1 flame test.
Internal wiring of electronic equipment and appliances. Tags may indicate the following:
"600 volts Peak for Electronic use only".